Optimal Application of Pinch Power Analysis in Hybrid System Sizing and for electric vehicle charging stations

Original scientific paper

Journal of Sustainable Development of Energy, Water and Environment Systems
ARTICLE IN PRESS (scheduled for Vol 14, Issue 03 (SDEWES 2025)), 1140724
DOI: https://doi.org/10.13044/j.sdewes.d14.0724 (registered soon)
Bouthayna Slimani , Aboubekr Allam, Hassan Zahboune, Smail Zouggar, Mohamed Laarbi Elhafyani, Taoufik Ouchbel
Mohammed First University, Oujda, Morocco

Abstract

This study proposes an optimisation framework dedicated to the optimal sizing of a hybrid renewable energy system composed of photovoltaic generation, wind power generation, and a battery energy storage system. The system is governed by an energy management system integrating the Pinch Power Analysis method, and the obtained results are validated using the Hybrid Optimization Model for Electric Renewables software. This framework is applied to a case study in the city of Oujda in Morocco, considering a residential electricity demand coupled with charging of electric vehicles. The results indicate that improving energy reliability requires higher installed generation and storage capacities. They show that the levelized cost of energy of the system composed of photovoltaic generation and battery energy storage (0.083 €/kWh) is lower than that of the configuration combining wind power generation, photovoltaic generation, and battery energy storage (≈ 0.10 €/kWh) for a loss of power supply probability below two percent. However, the integration of wind power reveals favourable temporal complementarity with photovoltaic generation. This complementarity significantly reduces storage requirements, stabilises battery state of charge cycles, and limits the deep discharges observed in the configuration composed only of photovoltaic generation and battery energy storage. The analysis is further extended through a sensitivity assessment of the electricity demand associated with electric vehicle charging, corresponding to 737 charging sessions per year with one charging station and 484 sessions per year with two charging stations. This increase in electricity demand raises the overall load while inducing only a limited impact on economic and reliability indicators, thereby confirming the ability of the system to adapt dynamically to variations in demand. In addition, surplus electricity production is exported to the electrical grid, which improves the economic viability of the studied systems.

Keywords: Energy Management System, Electric Vehicle, Levelized Cost of Energy, Loss of Power Supply

Creative Commons License
Views (in 2026): 31 | Downloads (in 2026): 10
Total views: 31 | Total downloads: 10

DBG