The advanced technologies in communication, distributed generation, cyber security, and advanced metering infrastructure of smart grid enhance the efficiency, reliability, and flexibility of the power grid [1]. Due to preset fashion and behaviour of suppliers and consumers, smart grid improves the competence, reliability, economics and sustainability of the fabrication and distribution of electricity. Due to different protocols, self remedial and intelligent communication sharing transportation, smart grid provides different techniques and algorithms to use energy more sensibly and effectively at demand side [2]. Demand Side Management (DSM) encourage and assist the user to shift their load from peak time slots (where the demand of energy is too high) to off peak time slots (where the demand of energy is low) [3]. Recently, one of the crucial DSM activities is Demand Response (DR), it is presumed that DR is a subset of DSM in broader aspect. DR is defined as the tariffs or program established to influence the end users to reshape their energy consumption profile in response to electricity price [4]. Among different techniques, i.e. direct load control and smart metering encourage the user to shift their load [5]. Demand management algorithm using the net metering techniques in which customer are encouraged to install renewable sources at demand side and extra generation will be sent back to utility [6]. Real time demand response, also a model used in when real time data is provided by the customer to utility [7]. Game theoretic model, incentive based energy consumption algorithm, autonomous three layered structure model and Vickrey Clarke Groove Mechanism are the techniques of DSM that manage the consumption in different prospectus [8]. Game theoretic method is also method implemented to get discussed results [9]. Some heuristic policies are also introduced to manage the energy consumption when it exceeds the threshold point [10]. Some techniques minimize the energy cost while some reduce the Peak to Average Ratio (PAR) but in limited amount. Table 1 gives all the described information about heuristic techniques used to attain the mentioned purpose. Limitation of each technique is mentioned briefly in referenced table. After visualizing limitation of all techniques we planned the algorithm that reduce the overall energy payment for user and reduce PAR in greater amount. Our algorithm will consider the user comfort as well. A new model of Real Time Pricing (RTP) will be introduced in coming sections in which a user will have to sufficient time to schedule the operation of household load.
Heuristic techniques
Techniques names | Aims and objectives | Descriptions | Limitations |
---|---|---|---|
Hybrid technique [Genetic Algorithm (GA) and Particles Swarm Optimization (PSO)] [11] | Minimization of cost and PAR | Distributed energy resources and energy resources system in Home Energy Management System (HEMS) | User comfort is ignored |
Evolutionary Algorithm (EA) [12] | Cost reduction | Energy optimization in household, commercial and residential consumption areas | System complexity is increased |
Integer Linear Programming (ILP) [13] | Cost and PAR reduction | Categorizing/classification of household contrivances using day ahead pricing model | PAR is not considered |
Dynamic Programming (DP) [14] | Cost and PAR reduction | Energy consumption behavior optimization with high penetration of renewable sources | System complexity is increased, user comfort is ignored as well |
Genetic Algorithm (GA) [15] | Cost reduction and user comfort | Division of operation period, as a result cost reduced and energy is optimized | System deals with large number of contrivances in multiple sectors results in enhancement of system complexity |
Genetic Algorithm (GA), Binary Particle Swarm Optimization (BPSO), Ant Colony Optimization (ACO) [16] | Cost and PAR reduction with limited user comfort | Using satisfaction and renewable sources integration considered, schedule the load | System complexity and computational time are increased |
Genetic Algorithm (GA) [17] | Cost reduction and user comfort | Energy consumption behavior optimization using renewable incorporation | PAR is ignored and challenges in considering renewable sources are not addressed |
Hybrid technique [Linear Programming (LP) & Binary Particle Swarm Optimization (BPSO)] [18] | Cost reduction and user comfort maximization | Interruptible contrivances are considered for schedule the operation under day ahead pricing umbrella | PAR is not considered |
Fractional Programming (FP) [19] | Electricity cost reduction | Cost efficient model under distributed energy sources and practical implementation of the proposed model | PAR and user comfort are not considered |
Genetic Algorithm (GA) [20] | Cost and PAR reduction | Radial electrical network model is used to test the proposed algorithm | System complexity and computational time is increased |
Harmony Search Algorithm (HSA) [21] | Basic overview of Harmony Search Algorithm (HSA), its structure and applications | Improved and hybrid (Harmony Search Algorithm) HSA with applications | Real time implementation is not considered |
Hybrid technique [Enhance Differential Evolution (EDA) & Harmony Search Algorithm (HSA)] [22] | Startup and generation cost of Renewable Energy Sources (RES) | IEEE standard bus system is used to verify the model | Computation time is increased |
Binary Particle Swarm Optimization (BPSO) [23] | Minimization of energy cost considering user preferences | Simplicity and robustness of Binary Particle Swarm Optimization (BPSO) | Computational time increase with respect to division of time slots |
Genetic Algorithm (GA) [24] | Minimization of energy cost, PAR and awaiting time | Generic model of DSM with Energy Management Controller (EMC) using RTP | User comfort is not addressed |
Single knapsack [25] | Optimization of energy consumption using six layers architecture | Comprehensive model for energy management addressing six layers architecture | In real time and practical scenario, architecture become more complex |
In time varying pricing tariffs, the proposed operation is divided into different time slots. The price of electricity varies according to different time slots. The prices are mainly higher from 6 PM evening to 10 PM night and lower at 12 AM night to 5 PM evening. Different pricing schemes as discussed in Khan et al. [26] are implemented by the utility on consumer. RTP is one of the major pricing schemes mainly used in European countries, in which the prices of electricity are declared after every hour for the next coming hour. Day Ahead Pricing (DAP) can be more effective because consumers can get sufficient times to plan their electricity consumption schedule, while hourly pricing can be boring for consumers. RTP can prove to be the most efficient pricing scheme, benefiting every stake holder involved and optimized by using the automated control system for the load [27]. The further type of RTP is DAP, in which prices of next 24 hours are defined day ahead. Second pricing scheme is Time of Use (TOU) pricing, which is mainly used in Indo-Pak region. In TOU pricing the prices are usually high at peak hours because high demand of energy, and low at off peak hours because low demand of energy. The more complex type of TOU pricing is seasonal TOU pricing in which prices varies according to season (two or more times in a year). Another important type which is considered to be more essential for DR is Inclining Block Rates (IBR). Inclining block rates structures charge a higher rate for each incremental block of consumption. As the consumption of energy increases, the rate of energy per kWh increases [28].
From all above previous literature we can draw a conclusion that:
In all previous work, the RTP model is used in which prices are changed after every hour, as a reset and user struggle and have not a sufficient time to schedule the operation of his household load;
No one method was proposed previously that takes into account all of three particulars, i.e. energy cost minimization, PAR reduction and user comfort.
We proposed a model in which takes into account all of three particulars cost minimization, PAR reduction and user comfort without any complexity in system.
We proposed an algorithm that uses small number of contrivances to schedule the operation. In our system we take into account all of three particulars cost minimization, PAR reduction and user comfort. Our model will be simple and less complicated.
The rest of this paper is organized as: the system model is introduced in Section II. Problem formulation and algorithm description are presented in Section III. Simulation results are provided in Section IV. The paper is concluded in Section V.
In this section, we present overall contribution towards this paper. We will define PAR according to parameters and its complete profile and impact on overall electrical system. Then we discuss of RTP and Pricing Function (PF) for our proposed model. Our system model is different from Khomami and Hossein Javidi [29], because in [29] RTP is to be implemented in such a way that prices are changed after every hour so that customer have insufficient time to schedule their load. In my system model i implemented such a RTP model that prices are not changed more than three times in a day. In such a model a customer have sufficient time to schedule the operation of their load according to demand.
Let us consider the residential setup that consist of 5 devices with variable energy consumption and categorized as in Table 2: must run and controllable devices that are interruptible and non- interruptible controllable devices. Must run start operation immediately at any time, e.g. PC, TV. Interruptible load is a controllable load. In this load it is not only possible to postpone the operation but also to interrupt the operation and restore later on, e.g. Plug in Electric Vehicle (PEV) [30]-[32]. Interruptible load further classified into two categories, sequential load and non sequential load. The operation period of sequential load is same for whole given 10 days, e.g. if it operation time is 5 AM to 6 AM then it will remain same. While the operation period of non sequential load is not in sequence, it becomes active any time in given period. In non interruptible load, the control unit may only delay its operation. For example, air conditioner timer and washing machine, etc. They complete their operation in specific time without interrupting or delaying their operation. The intended period of time for which i am going to develop algorithm is 10 days. Each hour is marked as one time slot and 1 day is equal to 24 hours means 24 time slots (ts) so total numbers of time slots (T) are 24 × 10 = 240 time slots.
Power rating for household load
Household devices | Power rating [W] |
---|---|
Device 1 | 2,000 |
Device 2 | 1,000 |
Device 3 | 746 |
Device 4 | 150 |
Device 5 | 60 |
Prices are defined for peak time and off peak hours, i.e. 13 PKR/kWh for peak time and 7 PKR/kWh for off peak time. Fist all calculation is to be done on given data without any Consumption Control Unit (CCU). CCU is nothing but a smart meter that has a digital two way intelligent communication infrastructure, and is responsible for DSM at consumer side. The whole system model is summarized such as:
We developed narrative optimization based on inhabited model which reduce the energy cost for each residential consumer and reduce the PAR as well. Each device send operation signal towards CCU, CCU decides, signal could be acceptable or not according to demand of customer;
We draw suitable management profile for controllable load in the sense of economically for the consumer and the electrical system;
At last, we will make analysis on simulation results obtained from proposed algorithm. We see whether our algorithm effectively reduces the cost and PAR for overall aggregated load.
PAR is the ratio of maximum aggregated load consumed in a certain time frame and the average of the aggregated load. PAR informs about the energy consumption behaviour of the consumers and the operation of the power grid. As we employed only the RTP, at peak hours when demand is high, PAR mainly increase which result in destabilization of electrical power grid. While reduction in PAR, simultaneously enhance the stability and reliability of power grid and reduces the electricity bill of residential consumers. PAR does not change as the customer does not respond to change the parameter which is defined in next sections. Mathematically, representation of PAR for a residential unit as in:
(1)
(2)
where Lpeak and Lavg show the maximum aggregated load and average load in a time frame (ts), while ET(ts) represents the total energy consumption of devices in a time slot for intended operation. PAR is given by:
(3)
Pts is the total household power consumption in current time slot ts. We define a pricing function (φts) with a combined model of RTP and IBR, which represent the wholesale payment in time slot ts as a function of user’s power consumption:
(4)
where its, jts and Pts are the fixed parameters, and we have its≤jts. Discussed in next sections, combined model of RTP and IBR can effectively avoid load harmonization.
Suppose that D represents the set of all devices present in this household unit, while d represents the current device on which operation is to be performed. Then each device d∈D must act as either must run or controllable (interruptible or non-interruptible). The real time data is given in the form of 0 or 1, respectively, for all devices. We define a dual variable as a representation of status of device d∈D. We set a variable if the device d is active in current time slot ts. In other case we set .
According to given data, the ON or OFF state for each device d∈D with respect to time slots and days is given in Figure 1. From Figure 1, we analyze that device 1 is ON in each time slot in 10 days. For device 2 it can be seen that it is ON for all days in time slot 18 and for 7 days in time slots 12, 15 and 21. Device 2 is also ON for 4 days in time slots 6 and 9 and for 3 days in time slots 5, 7, 8, 10, 12, 13, 19 and 22, while at time slots 1, 2, 3, 4, 11 it remain OFF. In this way we check the device ON and OFF status in each time slot. Similarly, the ON and OFF status of all other devices can also be known easily by analyzing the Figure 1.
ON/OFF status of household load with respect to time slots and days
In device 3, it is seen that it remain ON for all 10 days in time slots 7, 8, 9, 15, 19, 20, 21 and 22 and 7 days in time slots 6, 16, 18, 23 and 24. Device 3 is also ON for 4 days in time slots 10 and 17 and for 3 days in time slots 1, and 14, while at time slots 2, 3, 4, 11, 12 and 13 it remain OFF. In device 4, it is seen that it remain ON for all 10 days in time slot 18 and for 4 days in time slot 6. It is seen that it remain ON for 3 days in time slots 7, 19 and 23 while except these time slots it remain OFF. Similarly, in case of device 5, it is seen that it remain ON for 7 days in time slot 18 and for 4 days in time slot 6. It is seen that it remain ON for 3 days in time slots 7, 19 and 23, while in remaining time slots it remain OFF.
According to predefined variable , the state of ON or OFF and operation of overall load in given 240 time slots for given real time data 10 days is defined. Figure 2 tells us the overall frequency profile (on status) of each appliance for our monitoring system for all 240 time slots. We have 240 time slots in 10 days. From Figure 2, we can easily analyze that the device 1 is ON in all time slots, device 3 is ON in 130 time slots in 10 days, and device 5 is ON in 120 time slots.
Devices frequency
Device 4 is ON for minimum time slots, i.e. 20 time slots for 10 days. In this way we check each device frequency for specific period of time in given days. And then estimate the overall household consumption for real time data and vice versa.
Let us denote that the whole intended operation period for all devices is T. We are going to calculate the power consumption of each device in their intended operation time slot cycle, i.e. ts∈T. For that purpose we categorize the given household residential load into several classes that are given below and have been discussed in previous section as well:
Must run load;
Interruptible load;
Non-interruptible load.
After categorizing the overall household load, we consider a system without CCU deployment, where each device d is assumed to start operation right after it becomes awake at its nominal power (αd).
Figure 3 shows the variation in electrical demand over particular period of time. In Figure 3 we can see that wattage consumed curve of device 1 is a straight line because it remains on for all 240 time slots and does not show the variation in demand for a specific time due to must run property.
Power consumption profile of household load
Similarly, we can see in second interruptible device that it consumes maximum power of 7,500 W in time slot 18 for whole period of 10 days and consume 5,500 W for time slots 12, 15 and 21. Device 2 consumes 3,000 W in time slots.
We note that the operation of different devices is influences by the preference of user. Different parameters of our model may be considered to capture different types of preference. In time differentiating pricing tariffs, the intended operation period is divided into several time slots, and the price of electricity varies across different time slots. For example, the prices may correspond to off peak, mid peak and on peak hours. We have different rates for energy consumption in RTP. In RTP, rates are defined at different levels of time slots, i.e. off peak hours where the energy rates are kept low because consumption is low and on peak hours where the rates are kept high because consumption increased during that time slots.
For above profiles the intended period of operation is divided into peak time and off peak time. Peak hours from 5 PM to 10 PM and the off peak or rest hours for the day are off peak hours (12 AM to 4 PM and 11 PM). According to RTP, the prices varies with time. We defined the prices, i.e. 13 PKR for peak time and 7 PKR for off peak time. According to that data we calculate the overall cost of all devices. From Figure 4, we can see that each device is consuming different power so the energy cost for each device is different. The device which has greater energy consumption bill in PKR represents that it starts operation many times during peak time slots because during peak time slots energy rates are high, i.e. 13 PKR per kWh.
Bill calculation when customer is informed by utility with respect to RTP
So the total energy cost after summing energy cost of all devices is 3,269.65 PKR that is great amount by the way due to lack of energy CCU with our system. After calculating overall cost of consumption of all the devices in given 240 time slots (off peak and peak time), we move forward on the load estimation of our system. In our load estimation section we define how the load damages the overall system performance as well as in economical point of view of consumer. We discuss how we shift the load from peak time slots to off peak time to give incentive in economical point of view to the consumer and best for the community growth and infrastructure.
Figure 5 explains the load curve for all devices collectively. In this way, we easily analyze the electrical demand in each time slot. This figure also shows the maximum and minimum electrical demand over a specific time for all the devices collectively. In figure we can see that the load is maximum at peak time slots and minimum at off peak time slots of total slots. As the consumption increases the calculated load increases, as a result PAR of a system increases and damage the system’s performance.
Histogram of PAR when only RTP is applied without CCU
Recall from eq. (3), PAR is the ratio of the maximum aggregated load consumed in a certain time frame and the average of the aggregated load. PAR informs about the energy consumption behaviour of the consumers and the operation of the power grid. In Figure 5 we can see that the load is consuming more power at time 18, 19, 20 and 21 during peak time slots (5 PM to 10 PM), where energy tariffs rates are high, which is not better for economical point of view for consumer. During these time slots the PAR is high which overload the electrical grid system and its performance is slowed down. Our aim is to minimize PAR to improve system performance to run smoothly. We also aim to shift the peak load to off peak time slots because the rates during off peak time slots are very low as compared to peak time slots to make economical use of energy in smart grid system.
When CCU is deployed with respect to RTP at demand side, the result in the form of DSM minimize the energy cost for residential user.
When DSM is done through RTP, results in reduction in cost, but increases PAR, which damages the grid stability. For this purpose a combine model of RTP and IBR is implemented.
Figure 6 is a block diagram of basic DSM scheme. From Figure 6 it is clear that CCU does not have any type of physical connection with must run load. It only schedules the controllable (interruptible and non-interruptible) household load according to the circumstances.
DSM through CCU
When we deploy CCU, the operation signal is received from the device. Initially the load will be either must run or controllable. If the load is must run, CCU ignore it. When the load is shift-able (controllable), CCU accept the operation signal, once the operation signal is accepted the device starts its operation immediately. From Figure 7, in must run, device is in OFF mode and will remain OFF but when the operation signal is accepted it becomes ON and activate itself without any delay and finish operation. If the device is non-interruptible then again it is in OFF mode and obviously it remains in OFF mode.
Different operating states of proposed algorithm
If it turns ON then a second inactive mode is developed. It goes to inactive mode with delay greater than zero and then active mode or directly from ON mode to active mode with zero delay and then finish the entered operation. If the device is interruptible controllable load, again if it is in OFF mode then it remains OFF. When it goes to OFF mode to ON mode it goes to inactive state. Now two states are developed, and performs dual operation between inactive and active modes or directly ON state to active state and then finish the operation.
By deploying CCU, the load at the peak time slots, mainly 5 PM to 10 PM are shifted to off peak time slots to reduce the energy cost for residential users. Thus, we formulate a scheduling problem that minimizes the expected energy payment of the user with respect to demand uncertainties. In each time slot ts as the demand information of the device is updated, the operation schedule of each controllable device can be rescheduled and the optimum power scheduling can be identified in real time as the solution of the following optimization problem for the minimization of expected cost from the current time slot ts. In Figure 8 we can see that by deploying CCU energy, the energy is minimized, i.e. 2,771 PKR.
Cost minimization by deployment of CCU
When RTP is charged during peak time when the demands of energy are usually high, PAR of a system has been disturbed which obviously disturb the overall system’s performance. To overcome this drawback and increase PAR, a combined model of RTP and IBR is implemented. According to Islamabad Electric Supply Company (IESCO), Pakistan, IBR are according to [33] as in Table 3.
IBR set by regulation authority
Tariff category/Particulars | Prices per kWh |
---|---|
1-100 units | 8.70 PKR |
101-300 nits | 10.20 PKR |
301-700 units | 14.00 PKR |
Above 700 units | 16.50 PKR |
Let the demand information of the device is known ahead of time and awakes devices in the upcoming time slots k>ts that are currently sleeping, only the probability with each device becomes awake at each time slot before the operation cycle begins:
(5)
where qd denotes the probability that device d does not become ON at any time within the DSM operation period.
In Figure 9, we can see that after deployment of CCU energy, the bar line at peak time slots is shifted to off peak time slots. When the load from more energy consumption slots is shifted to less and reliable slots, then we have reduction in PAR of overall aggregated load which improves the overall system’s performance.
Reduction of PAR and shifting of pea values by using RTP + IBR
When we implemented only RTP, the energy cost is minimized but unfortunately we get increase in PAR of overall household load. But with involved IBR we got reduction in PAR ratio as well. In this section we describe the impact of involving IBR with RTP model.
As in Figure 10, in RTP when pricing parameters changes from its to jts, PAR of the system is disturbed. When its=jts then there will be no issue with PAR of the system. When it shows dual behaviour its⇌jts then IBR must be a part of our system. Simulation results for the average daily payment of the user as well as the average PAR of the system for different values of parameter are depicted in Figure 10. Intuitively, when parameter is equal to one, i.e. when its=jts for all time slots T, the performance of our proposed method is the same as the one in which effect of IBR is ignored. However, by increasing the pricing parameters, the payment increases, as the user has to pay more every time that its load exceeds threshold pth as in Figure 10. Increasing pricing parameters improves PAR of the system. Surprisingly, results shows that greater the consumption, greater the cost and PAR reduction. So here we draw a statement that DSM encourages the user to use the power more wisely and effectively by shifting the load from peak time to off peak time. In my simulation model, pth is set to (threshold power consumption level) 23.5 kW for 24 time slots. As the load exceeds the threshold point (23.5 kW), CCU shifts behind to off peak slots and that results in reduction in PAR.
Difference between two profiles of PAR and cost without and with CCU
The overall comparison profile of system without and with deployment of consumption control unit is depicted in Figure 10. The overall calculated comparative result in numeric form is illustrated in Table 4. Both profiles are depicted and differentiated before deployment of consumption control unit and after deployment of consumption control unit.
Concluded results of cost and PAR reduction
Particulars | Without CCU | With CCU | Reduction [%] |
---|---|---|---|
Cost | 3,269.65 PKR | 2,771.9 PKR | 15.22 |
PAR | 2.80 × 104 W | 2.35 × 104 W | 16.07 |
In this paper, i developed a residential DSM algorithm in presence of load uncertainty. I measured the benefits for both residential customer and utility via minimizing the energy cost as well as PAR. I formulated an optimization problem to minimize the electricity payment for residential users in the situations where only an estimate of the future demand is available. I focused on a scenario where RTP is combined with IBR to balance residential load to achieve reduction in PAR. Scientific contributions of work have covered different areas. A simulation results shows that a unique model of RTP provides a sufficient time to schedule the operation more easily, in which prices are changed only 2 to 3 times in day instead of hourly fluctuation. In fact, proposed model of RTP is a new shape of RTP in class of dynamic pricings. A results show that the proposed algorithm reduces the energy cost for users, encouraging them to participate in DSM scheme. Exploiting IBR with RTP tariffs can help to avoid load synchronization, and the combination of general RTP method with my algorithm reduces PAR of the total load. The latter provides incentives for utilities to support implementing the proposed algorithm. So this is proper intelligent algorithm for economical use of energy in smart electrical network system.
In future i have aim to integrate the renewable sources for more expediency of residential consumer. This will provide automatic switching to user during peak time slots. My system model can be extended to scenarios when a user faces deep trouble during load shedding. In this case of constraint of renewable sources can help to tackle this situation.
GTES: An Optimized Game Theoretic Demand Side Management Scheme for Smart Grid ,IEEE Syst. , Vol. 8 (2),pp 588-597 , 2014, https://doi.org/https://doi.org/10.1109/JSYST.2013.2260934
, Energy Management and Smart Grid ,Energies , Vol. 6 (4),pp 2262-2290 , 2013, https://doi.org/https://doi.org/10.3390/en6042262
, Optimal Residential Community Demand Response Scheduling in Smart Grid ,Applied Energy , Vol. 210 ,pp 1280-1289 , 2018, https://doi.org/https://doi.org/10.1016/j.apenergy.2017.06.066
, Time Based Pricing and Electricity Demand Response: Existing Barriers and Next Steps ,Utilities Policy , Vol. 40 ,pp 15-25 , 2016, https://doi.org/https://doi.org/10.1016/j.jup.2016.04.001
, - , Designing Cost Effective Demand Management Contracts Using Game Theory, Proceedings of the IEEE Power Eng. Sc. 1999 Winter Meeting (Cat. No. 99CH36233), 1999
Using Utility Information to Calibrate Customer Demand Management Behavior Model ,IEEE Transaction on Power System , Vol. 16 (2),pp 317-322 , 2001, https://doi.org/https://doi.org/10.1109/59.918305
, Real Time Demand Response Model ,IEEE Transaction on Smart Grid , Vol. 1 (3),pp 236-242 , 2010, https://doi.org/https://doi.org/10.1109/TSG.2010.2078843
, Advanced Demand Side Management for the Future Smart Grid Using Mechanism Design ,IEEE Transaction on Smart Grid , Vol. 3 (3),pp 1170-1180 , 2012, https://doi.org/https://doi.org/10.1109/TSG.2012.2203341
, Autonomous Demand Side Management Based on Game-Theoretic Energy Consumption Scheduling for the Future Smart Grid ,IEEE Transaction on Smart Grid , Vol. 1 (3),pp 320-331 , 2010, https://doi.org/https://doi.org/10.1109/TSG.2010.2089069
, Dynamic Pricing in Smart Grids Under Thresholding Policy: Algorithms and Heuristics ,IEEE Trans. on Smart Grid , Vol. 10 (3),pp 3415-3429 , 2019, https://doi.org/https://doi.org/10.1109/TSG.2018.2825997
, An Optimized Home Energy Management System With Integrated Renewable Energy and Storage Resources ,Energies , Vol. 10 (4),pp 549 , 2017, https://doi.org/https://doi.org/10.3390/en10040549
, Demand Side Management in Smart Grid Using Heuristic Optimization ,IEEE Trans. on Smart Grid , Vol. 3 (3),pp 1244-1252 , 2012, https://doi.org/https://doi.org/10.1109/TSG.2012.2195686
, Residential Power Scheduling for Demand Response in Smart Grid ,Int. J. Electr. Power & Energy Syst. , Vol. 78 ,pp 320-325 , 2016, https://doi.org/https://doi.org/10.1016/j.ijepes.2015.11.099
, Load Scheduling and Power Trading in Systems With High Penetration of Renewable Energy Resources ,IEEE Trans. on Smart Grid , Vol. 7 (4),pp 1802-1812 , 2015, https://doi.org/https://doi.org/10.1109/TSG.2015.2435708
, An Optimal Power Scheduling Method for Demand Response in Home Energy Management System ,IEEE Trans. on Smart Grid , Vol. 4 (3),pp 1391-1400 , 2013, https://doi.org/https://doi.org/10.1109/TSG.2013.2251018
, Exploiting Heuristic Algorithms to Efficiently Utilize Energy Management Controllers with Renewable Energy Sources ,Energy and Build , Vol. 129 ,pp 452-470 , 2016, https://doi.org/https://doi.org/10.1016/j.enbuild.2016.08.008
, Real Time Information Based Energy Management Using Customer Preferences and Dynamic Pricing in Smart Homes ,Energies , Vol. 9 (7),pp 542 , 2016, https://doi.org/https://doi.org/10.3390/en9070542
, Residential Load Scheduling in Smart Grid: A Cost Efficiency Perspective ,IEEE Trans. on Smart Grid , Vol. 7 (2),pp 771-784 , 2016, https://doi.org/https://doi.org/10.1109/TSG.2015.2419818
, Distributed Demand Side Management with Energy Storage in Smart Grid ,IEEE Transaction on Parallel Distribution Systems , Vol. 26 (12),pp 3346-3357 , 2015, https://doi.org/https://doi.org/10.1109/TPDS.2014.2372781
, Demand Planning in Smart Homes ,IEEE Lat. Am. Trans. , Vol. 14 (7),pp 3247-3255 , 2016, https://doi.org/https://doi.org/10.1109/TLA.2016.7587627
, Harmony Search Method: Theory and Applications ,Journal of Computational Intelligence and Neuroscience , Vol. 2015 ,pp 10 , 2015, https://doi.org/https://doi.org/10.1155/2015/258491
, A Hybrid Harmony Search Algorithm with Differential Evolution for Day-Ahead Scheduling Problem of a Microgrid with Consideration of Power Flow Constraints ,Appl. Energy , Vol. 183 ,pp 791-804 , 2016, https://doi.org/https://doi.org/10.1016/j.apenergy.2016.09.035
, Realistic Scheduling Mechanism for Smart Homes ,Energies , Vol. 9 (3),pp 1-28 , 2016, https://doi.org/https://doi.org/10.3390/en9030202
, A Generic Demand-Side Management Model for Smart Grid ,International Journal of Energy Research , Vol. 39 (7),pp 954-964 , 2015, https://doi.org/https://doi.org/1.1002/er.3304
, An Enhanced System Architecture for Optimized Demand Side Management Smart Grid ,Journal of Applied Sciences , Vol. 6 (5),pp 1-23 , 2016, https://doi.org/https://doi.org/10.3390/app6050122
, - , Load Forecasting and Dynamic Pricing Based Energy Management in Smart Grid ‒ A Review, Proceedings of the IMTIC 2015: 4th International Multi TopIc Conference, 2015
Tackling the Load Uncertainties Challenges for Energy Consumption Scheduling in Smart Grid ,IEEE Transaction on Smart Grid , Vol. 4 (2),pp 1007-1016 , 2013, https://doi.org/https://doi.org/10.1109/TSG.2012.2234769
, - , Demand Response Benefit for Load Management Through Heuristic Algorithm in Smart Grid, Proceedings of the 2018 International Symposium on Recent Advances in Electrical Engineering, 2018
- , An Efficient Home Energy Management System for Autommated Residential Demands Response, Proceedings of the 13th International Conference on Environment and Electrical Engineering, 2013
Energy Consumption Scheduler for Demand Response Systems in the Smart Grid ,Journal of Information Science and Engineering , Vol. 28 ,pp 955-969 , 2012, https://doi.org/https://doi.org/10.6688/JISE.2012.28.5.9
, Scheduling Power Consumption with Price Uncertainty ,IEEE Transaction on Smart Grid , Vol. 2 (3),pp 519-527 , 2011, https://doi.org/https://doi.org/10.1109/TSG.2011.2159279
, - , A Survey of Direct Residential Energy Consumption Controlling Techniques for Autonomous DSM in Future Smart Grid Communications, Proceedings of the 8th International Conference on Broadband and Wireless Computing, Communication and Applications, 2013
- , , Government of Pakistan, 2012